All posts by: Siwenoid

About Siwenoid

FAQ

2025-04-11

If you have any question to our product don’t hesitate to contact us! What is miminum HW requirement? During develoment we always keep the code optimized to run on the lowest possible HW. This not only reduces installation cost, but also increases the responsivness of user interface and provides a better user experience.For general use: […]

Android app

2025-04-11

SIWENOID android app provides full functionality over the subsystems. It’s GUI has all the equivalent interfaces like desktop application provides in text mode. Search function helps to find a certain datapoint in hierarchy. Many features make SIWENOID app unique on the market. We recommend for the following applications: See video: GALLERY videos.

SIEMENS control panel integration is always our first priority. We started the development to integrate the legendary Algorex fire alarm panel more than a decade ago. Now we step by step follow the evolution of SINTESO product family of SIEMENS. There is no any difference in SINTESO and CerberusPro product line integration. Both is based […]

AUCHAN hypermarket chain has been our key account in fire and security solutions for almost two decades. The culmination of this long term cooperation is the installation of a centralized integrated security center. Fire alarm systems and intrusion systems of 18 hypermarkets and a few supermarket is integrated into a central security dispatcher room in […]

BorsodChem is a hungarian chemical raw material manufacturing company. The factory are is protected by 68 fire alarm panels and ~7000 peripheries. The software was ordered at the end of an exciting tender process. Each participant had to make a test installation for a 2 months period. During this time end-user asked for some special […]

SIEMENS MM8000 is superseded with SIWENOID v2 management system. 18 pcs of SINTESO control units are interconnected in two native loop (SafeDlink). The SIWENOID communicates on two path with the SafeDlink net. The system consist of 3 client workstation. One at the fire department, one at the maintenance brigade and one at central dispacher room. […]

Hot-standby feature

2025-02-28

Hot-standby feature is available! For the highest reliability requirements we provide a parallel server solution. During normal operation the primary server is responsible for the subsystem- and client communication. Both server has SQL database and they are written simultaneously. If primary server fails the connection loss is detected by the secondary server and respective clients […]

45pcs of SIEMENS fire alarm control units are integrated into our SIWENOID system at Budapest Airport.   It is one of our biggest installation with more than 16.000 detectors. Fire alarm messages are transfered also to a foreign database which is a central DB for scada system located at the airport. Several new features were […]

Paradox EVO192 was integrated into SIWENOID using the PRT3 printer module and the ASCII protocol to communicate with the panel. It’s a reliable and versatile interface for building management hosts. Now we also added the capability of communication with IP150 and IP150+. It’s advantage that panel programming can also be done through this path.  The […]

We installed SIWENOID in a Hungarian NATO airport to visualize the fire alarm events of 10 fire alarm panels. Two different communication protocols are used on the site: It integrates Algorex fire control unit with ISO1745 and SIEMENS Sinteso control unit with BACnet communication. Each control unit is connected through LAN to the management system. […]

Beaglebone solution

2023-04-29

We provide a solution with a Beaglebone single board computer. Thanks to its Linux OS, entire SIWENOID can run on it. We use these conpact and energy efficient as servers. We use them for they have no moving parts, what makes them reliable. It can be installed in a control panel and supply power by […]

CCTV handling

2022-03-18

Siwenoid can interface with many CCTV systems. Surviallence cameras can be marked on maps, can be assigned to datapoints so when an alert comes you’ll get the picture!

Users, datapoints, events can all have different permissions, even in relation to the others. Every user has its own, customizable permission levels

Minimax FMZ5000 fire and extiguishing control panel integration has already been available for almost a decade. Panel is connected to LAN or WAN using device server. Datapoints are automatically imported from a list file of the panel tool. A single control unit or many control units interconnected on a site then SIWENOID provides a reliable […]

Siwenoid V2 building management software Built on the success of its predecessor and optimised for the newest trends in the fire prevention and access control industry. After years of development we released Siwenoid V2 in September 2017. Key features of Siwenoid V2 Dynamic, fast java application Server – client application with MySQL OS independent (Windows, […]

On a site as big as a 20.000 seat stadium fire protection and access control is a must. Security personnel must be fully aware of every movement and fire hazard in every situation. They must be ready to open and close zones instantly in case of emergency. They choose to integrate the LST fire and […]

Watch the software in action. How it handles alarms, CCTV, data points, maps, and many more.

Security Integration software for management Siwenoid is an integrated security management software that runs on Windows, Linux or Mac OS X. Compatible with several fire/intrusion panels and CCTV DVR/NVRs. Easy to use engineering and user interface. Script enabled to define interactions between subsystems. Flexible, reliable, scalable, competitive without any compromise.

LST integration

2020-09-29

LST fire alarm panel is popular in mid-sized installations and it’s designed as a modular system. It has been integrated into SIWENOID for almost a decade. SIWENOID use serial interface (with device server) to communicate with it. The commissioning of a graphic management system become extremly easy and fast. BC216 and the BC600 are also integrated.  […]

A shopping mall and conference center on the permises of Budapest. On the site there are several Cerberus Pro MP5 Fire alarm panels communicating with each other in speedlink and BACnet is used to communicate with Siwenoid V2. More than 4000 detectors are monitored throught Siwenoid, with instant printing of every event. 1 PC configuration (Server […]

You can access all important features of Siwenoid via our android app. Manage alerts on the move!

3 Siemens Cerberus pro fire alarm system connected together with Siwenoid.

Auchan ordered the integration of their Siemens fire alarm panels, Siemens intrusion panels, and Honeywell Galaxy intrusion panels. Three different protocols are used for the communication. The systems work together in perfect harmony.